Mechanical Tunable Free Running DRO 
Frequency Range in GHz (1) 3.0 - 8.99  9.0 -13.99  14.0-16.0  16.01-18.0*
Mechanical  Tuning Bandwidth (min.) +/- 25 MHz +/- 25 MHz +/- 25 MHz +/- 25 MHz
Output Power (over temperature) (min) (2) +12 dBm +11 dBm +10 dBm +8 dBm
Frequency Stability (over temp) (max) +/- 3 ppm/C +/- 5 ppm/C +/- 5 ppm/C +/- 5 ppm/C
Power variation (over temperature) (max) +/- 1.0 dB +/- 1.5 dB +/- 1.5 dB +/- 1.5 dB
Power variation (over tuning range) (max) +/- 1.0 dB +/- 1.0 dB +/- 1.0 dB +/- 1.0 dB
Pulling (1.5:1 VSWR) (max) +/- 0.5 MHz +/- 0.5 MHz +/- 0.5 MHz +/- 0.5 MHz
Pushing (max) 20 KHz/V 20 KHz/V 20 KHz/V 20 KHz/V
Harmonics (typ) -18 dBc -20 dBc -25 dBc -25 dBc
Spurious (typ) -75 dBc -75 dBc -75 dBc -75 dBc
Typical Phase Noise (3)  @ 1KHz offset -65 dBc/Hz -63 dBc/Hz -60 dBc/Hz -53 dBc/Hz
                                    @ 10KHz offset -95 dBc/Hz -95 dBc/Hz -93 dBc/Hz -83 dBc/Hz
                                    @ 100KHz offset -123 dBc/Hz -121 dBc/Hz -120 dBc/Hz -113dBc/Hz
                                    @ 1MHz offset -140 dBc/Hz -140 dBc/Hz -135 dBc/Hz -130 dBc/Hz
Operating Temperature (base plate) (4)

-10 to +60 deg C

Power Supply (5)

+12 +/- 3% VDC, 90 mA typ

RF Connector:

SMA Female

DC Connector

Solder pin

Size (6) 1.00"x1.75"x.63" (25.4mm x 44.5mm x 16.0mm)
Outline: DC200104 Rev 1A
* Higher frequency units (17 to 23 GHz) available in DC200102 Rev. 4 housing, consult factory.

 

Notes:
(1)  Accuracy +/- 2 MHz max
(2) Typical power level at least 1 dB higher than minimum.  
     Higher power level available
(3) Guaranteed phase noise is 5 dB higher than typical
(4) Wider temperature range available
(5) +12V nominal, other voltages customer to specify
(6) Height dimension of .63" exclude tuning screw height (.25" max), Height to be .75" under 8 GHz.
Unit performances frequently meet or exceed typical level

Applications: Small size and cost effective, temperature stable with excellent phase noise and low microphonics.  Frequency is field adjustable mechanically, ideal for commercial communication: Fiber Optics, up/down converter or tranceiver LO applications, where low cost, excellent phase noise and frequency stability are optimized to system performance requirements. 